Case Study

Environmental impact of port operations in the port of Almeria

Aptica

Need

Through the prediction of the environmental impact of port operations, the aim is to create a series of algorithms that allow the optimisation of the activity in the port of Almeria. This is the objective of the project developed by Aptica, in collaboration with the Polytechnic University of Madrid, called ACOPIAIA – Ports 4.0 (Algorithm for the Characterisation, Optimisation and Prediction of Environmental Impact based on Artificial Intelligence in Ports 4.0).

This project is supported by the Port Authority of Almeria, which will provide the port area for the installation of the monitoring network using Kunak AIR Pro stations for the initial data collection and validation of the algorithms.

The ACOPIAIA – Ports 4.0 project has been awarded by Red.es of the 2021 call for aid for research and development projects in artificial intelligence and other digital technologies and their integration into value chains.

Solution

For the environmental impact measurement project, a network of 7 Kunak AIR Pro air quality stations has been deployed with the capacity to measure multiple pollutants such as CO, NO, NO2, O3 and SO2 and suspended particles (PM1, PM2,5, PM4, PM10, TSP and TPC), as well as various meteorological variables such as temperature, humidity, pressure and dew point.

In addition, 4 of the stations have a sound level meter to measure noise pollution arising from port activity.

Results

Accurate and reliable information on the environmental impact of port operations through real-time monitoring of gases and particles for the development of algorithms to optimise port activity.

In addition, control of the environmental impact and the impact on workers with a focus on people’s health.

 

Red.es - Plan de Recuperación, Transformación y Resiliencia

 

Project details

Customer: Aptica

User: Aptica

Location: Port of Almeria, Spain

Sector:

Year: 2023

Parameters:

  • CO, NO, NO2, O3 and SO2
  • PM1, PM2,5, PM4, PM10, TSP and TPC
  • Sound level meter
  • Temperature, humidity, pressure and dew point.

Solutions

  • AIR ProProfessional air quality monitoring station
    Air quality monitor

    AIR Pro

    The most accurate air quality monitoring station

    SENSOR-BASED | BEST AVAILABLE ACCURACY

    Benefits

    • Multi-pollutant
    • Smart cartridge system
    • Fully autonomous
    • Real-time data
    • Proven accuracy
    See more
  • AIR CloudAir quality software
    Air quality software - Kunak AIR Cloud

    AIR Cloud

    Multipurpose air quality software for professionals

    REAL-TIME DATA | ALWAYS UPDATED

    Benefits

    • Secure and condifential
    • Air quality reporting
    • Advanced data analysis and visualisation
    • Reliable data guaranteed
    • Data sharing and integration
    See more
  • Carbon monoxideReliable real-time data on CO
    Carbon-monoxide

    Carbon monoxide

    Reliable information about carbon monoxide

    GASPLUG TECHNOLOGY | PATENTED DESIGN

    Specs

    • Electrochemical
    • R2 >0.85
    • Range: 0-12,000 ppb (Type A) | 0-500 ppm (Type B)
    • Resolution: 1 ppb (Type A) | 0.01 ppm (Type B)
    • 24 months of operating life
    See more
  • Nitric oxideReliable real-time data on NO
    Nitric_oxide_cartucho

    Nitric oxide

    Reliable information about nitric oxide

    GASPLUG TECHNOLOGY | PATENTED DESIGN

    Specs

    • Electrochemical
    • R2 >0.9
    • Range: 0-5,000 ppb
    • Resolution: 1 ppb
    • 24 months of operating life
    See more
  • Nitrogen dioxideReliable real-time data on NO2
    Nitreogen_dioxide

    Nitrogen dioxide

    Reliable information about nitrogen dioxide

    GASPLUG TECHNOLOGY | PATENTED DESIGN

    Specs

    • Electrochemical
    • R2 >0.85
    • Range: 0-12,000 ppb (Type A) | 0-500 ppm (Type B)
    • Resolution: 1 ppb (Type A) | 0.01 ppm (Type B)
    • 24 months of operating life
    See more
  • OzoneReliable real-time data on O3
    Ozone

    Ozone

    Reliable information about ozone

    GASPLUG TECHNOLOGY | PATENTED DESIGN

    Specs

    • Electrochemical
    • R2 >0.9
    • Range: 0-2,000 ppb
    • Resolution: 1 ppb
    • 24 months of operating life
    See more
  • Sulphur dioxideReliable real-time data on SO2
    Sulphur_dioxide

    Sulphur dioxide

    Reliable information about sulphur dioxide

    GASPLUG TECHNOLOGY | PATENTED DESIGN

    Specs

    • Electrochemical
    • R2 >0.7
    • Range: 0-10,000 ppb
    • Resolution: 1 ppb
    • 24 months of operating life
    See more
  • Particulate MatterReliable real-time data on suspended particles

    Particulate Matter

    Reliable information about particulate matter

    GASPLUG TECHNOLOGY | PATENTED DESIGN

    Specs

    • Optical particle counter
    • Up to R2 >0.9
    • Range: 0-1,000 | 0-2,000 | 0-10,000 ppb
    • Resolution: 1 μg/m3
    • 24 months of operating life
    See more
Air quality monitor

AIR Pro

The most accurate air quality monitoring station

SENSOR-BASED | BEST AVAILABLE ACCURACY

Benefits

  • Multi-pollutant
  • Smart cartridge system
  • Fully autonomous
  • Real-time data
  • Proven accuracy
See more
Air quality software - Kunak AIR Cloud

AIR Cloud

Multipurpose air quality software for professionals

REAL-TIME DATA | ALWAYS UPDATED

Benefits

  • Secure and condifential
  • Air quality reporting
  • Advanced data analysis and visualisation
  • Reliable data guaranteed
  • Data sharing and integration
See more
Carbon-monoxide

Carbon monoxide

Reliable information about carbon monoxide

GASPLUG TECHNOLOGY | PATENTED DESIGN

Specs

  • Electrochemical
  • R2 >0.85
  • Range: 0-12,000 ppb (Type A) | 0-500 ppm (Type B)
  • Resolution: 1 ppb (Type A) | 0.01 ppm (Type B)
  • 24 months of operating life
See more
Nitric_oxide_cartucho

Nitric oxide

Reliable information about nitric oxide

GASPLUG TECHNOLOGY | PATENTED DESIGN

Specs

  • Electrochemical
  • R2 >0.9
  • Range: 0-5,000 ppb
  • Resolution: 1 ppb
  • 24 months of operating life
See more
Nitreogen_dioxide

Nitrogen dioxide

Reliable information about nitrogen dioxide

GASPLUG TECHNOLOGY | PATENTED DESIGN

Specs

  • Electrochemical
  • R2 >0.85
  • Range: 0-12,000 ppb (Type A) | 0-500 ppm (Type B)
  • Resolution: 1 ppb (Type A) | 0.01 ppm (Type B)
  • 24 months of operating life
See more
Ozone

Ozone

Reliable information about ozone

GASPLUG TECHNOLOGY | PATENTED DESIGN

Specs

  • Electrochemical
  • R2 >0.9
  • Range: 0-2,000 ppb
  • Resolution: 1 ppb
  • 24 months of operating life
See more
Sulphur_dioxide

Sulphur dioxide

Reliable information about sulphur dioxide

GASPLUG TECHNOLOGY | PATENTED DESIGN

Specs

  • Electrochemical
  • R2 >0.7
  • Range: 0-10,000 ppb
  • Resolution: 1 ppb
  • 24 months of operating life
See more

Particulate Matter

Reliable information about particulate matter

GASPLUG TECHNOLOGY | PATENTED DESIGN

Specs

  • Optical particle counter
  • Up to R2 >0.9
  • Range: 0-1,000 | 0-2,000 | 0-10,000 ppb
  • Resolution: 1 μg/m3
  • 24 months of operating life
See more