Case Study

Cruise ship pollution monitoring in the APB ports

APB - Port Authority of the Balearic Islands

Need

With the aim of “monitoring air quality by measuring pollutant emissions in the air of the port area and acoustic levels”, the Balearic Islands Port Authority sought to design a network of air quality stations in the ports of Palma, Eivissa, Maó, Alcudia and La Savina.

This monitoring network will allow them to know the origins and magnitudes of pollutant and noise sources in order to study proposals that contribute to improving air quality and the quality of life of users and citizens.

Deployment of an environmental monitoring network for maritime transport emissions in the ports of the APB.

Solution

The joint venture formed by Kunak and Labaqua has deployed a network of 25 Kunak AIR Pro devices to monitor pollutant gas and particle parameters and noise pollution in real time in 8 ports of the Balearic Islands.

The data is collected and sent to a cloud platform available to the APB.

  • Deployment of a network of 25 Kunak AIR Pro stations: 8 in the port of Palma, 6 in Ibiza, 4 in Maó, 4 in Alcudia and 3 in La Savina.
  • SIAM environmental data management platform for the execution of pollutant dispersion models and rollback analysis.
  • Data analysis for the implementation of improvement plans.
  • A real-time information panel on air quality integrated into the port authority’s website.
  • Kunak AIR Cloud platform for the operational management of the sensor network.

Results

Development of an environmental monitoring solution for ports calibrated with the following functionalities:

  • Alarm system, alerts and statistics in real-time.
  • System for generating periodic reports.
  • Detection of episodes of increased pollution.
  • Remote management and calibration of equipment.
  • Development of advanced statistical protocols for obtaining high-quality and reliable data that provide high correlations with official stations and reference equipment.

Project details

Customer: APB - Port Authority of the Balearic Islands

User: APB - Port Authority of the Balearic Islands

Location: Balearic Ports, Spain

Sector:

Year: 2019

Parameters:

  • CO, O3, NO, NO2 SO2, PM1, PM2.5, PM4, PM10, Total Suspended Particles (TSP) and Total Particle Count (TPC).
  • Noise pollution.
  • Temperature, humidity and atmospheric pressure.
  • Wind direction and speed.

Solutions

  • AIR ProProfessional air quality monitoring station
    Air quality monitor

    AIR Pro

    The most accurate air quality monitoring station

    SENSOR-BASED | BEST AVAILABLE ACCURACY

    Benefits

    • Multi-pollutant
    • Smart cartridge system
    • Fully autonomous
    • Real-time data
    • Proven accuracy
    See more
  • AIR CloudAir quality software
    Air quality software - Kunak AIR Cloud

    AIR Cloud

    Multipurpose air quality software for professionals

    REAL-TIME DATA | ALWAYS UPDATED

    Benefits

    • Secure and condifential
    • Air quality reporting
    • Advanced data analysis and visualisation
    • Reliable data guaranteed
    • Data sharing and integration
    See more
  • Carbon monoxideReliable real-time data on CO
    Carbon-monoxide

    Carbon monoxide

    Reliable information about carbon monoxide

    GASPLUG TECHNOLOGY | PATENTED DESIGN

    Specs

    • Electrochemical
    • R2 >0.85
    • Range: 0-12,000 ppb (Type A) | 0-500 ppm (Type B)
    • Resolution: 1 ppb (Type A) | 0.01 ppm (Type B)
    • 24 months of operating life
    See more
  • Nitric oxideReliable real-time data on NO
    Nitric_oxide_cartucho

    Nitric oxide

    Reliable information about nitric oxide

    GASPLUG TECHNOLOGY | PATENTED DESIGN

    Specs

    • Electrochemical
    • R2 >0.9
    • Range: 0-5,000 ppb
    • Resolution: 1 ppb
    • 24 months of operating life
    See more
  • Nitrogen dioxideReliable real-time data on NO2
    Nitreogen_dioxide

    Nitrogen dioxide

    Reliable information about nitrogen dioxide

    GASPLUG TECHNOLOGY | PATENTED DESIGN

    Specs

    • Electrochemical
    • R2 >0.85
    • Range: 0-12,000 ppb (Type A) | 0-500 ppm (Type B)
    • Resolution: 1 ppb (Type A) | 0.01 ppm (Type B)
    • 24 months of operating life
    See more
  • OzoneReliable real-time data on O3
    Ozone

    Ozone

    Reliable information about ozone

    GASPLUG TECHNOLOGY | PATENTED DESIGN

    Specs

    • Electrochemical
    • R2 >0.9
    • Range: 0-2,000 ppb
    • Resolution: 1 ppb
    • 24 months of operating life
    See more
  • Sulphur dioxideReliable real-time data on SO2
    Sulphur_dioxide

    Sulphur dioxide

    Reliable information about sulphur dioxide

    GASPLUG TECHNOLOGY | PATENTED DESIGN

    Specs

    • Electrochemical
    • R2 >0.7
    • Range: 0-10,000 ppb
    • Resolution: 1 ppb
    • 24 months of operating life
    See more
  • Particulate MatterReliable real-time data on suspended particles

    Particulate Matter

    Reliable information about particulate matter

    GASPLUG TECHNOLOGY | PATENTED DESIGN

    Specs

    • Optical particle counter
    • Up to R2 >0.9
    • Range: 0-1,000 | 0-2,000 | 0-10,000 ppb
    • Resolution: 1 μg/m3
    • 24 months of operating life
    See more
Air quality monitor

AIR Pro

The most accurate air quality monitoring station

SENSOR-BASED | BEST AVAILABLE ACCURACY

Benefits

  • Multi-pollutant
  • Smart cartridge system
  • Fully autonomous
  • Real-time data
  • Proven accuracy
See more
Air quality software - Kunak AIR Cloud

AIR Cloud

Multipurpose air quality software for professionals

REAL-TIME DATA | ALWAYS UPDATED

Benefits

  • Secure and condifential
  • Air quality reporting
  • Advanced data analysis and visualisation
  • Reliable data guaranteed
  • Data sharing and integration
See more
Carbon-monoxide

Carbon monoxide

Reliable information about carbon monoxide

GASPLUG TECHNOLOGY | PATENTED DESIGN

Specs

  • Electrochemical
  • R2 >0.85
  • Range: 0-12,000 ppb (Type A) | 0-500 ppm (Type B)
  • Resolution: 1 ppb (Type A) | 0.01 ppm (Type B)
  • 24 months of operating life
See more
Nitric_oxide_cartucho

Nitric oxide

Reliable information about nitric oxide

GASPLUG TECHNOLOGY | PATENTED DESIGN

Specs

  • Electrochemical
  • R2 >0.9
  • Range: 0-5,000 ppb
  • Resolution: 1 ppb
  • 24 months of operating life
See more
Nitreogen_dioxide

Nitrogen dioxide

Reliable information about nitrogen dioxide

GASPLUG TECHNOLOGY | PATENTED DESIGN

Specs

  • Electrochemical
  • R2 >0.85
  • Range: 0-12,000 ppb (Type A) | 0-500 ppm (Type B)
  • Resolution: 1 ppb (Type A) | 0.01 ppm (Type B)
  • 24 months of operating life
See more
Ozone

Ozone

Reliable information about ozone

GASPLUG TECHNOLOGY | PATENTED DESIGN

Specs

  • Electrochemical
  • R2 >0.9
  • Range: 0-2,000 ppb
  • Resolution: 1 ppb
  • 24 months of operating life
See more
Sulphur_dioxide

Sulphur dioxide

Reliable information about sulphur dioxide

GASPLUG TECHNOLOGY | PATENTED DESIGN

Specs

  • Electrochemical
  • R2 >0.7
  • Range: 0-10,000 ppb
  • Resolution: 1 ppb
  • 24 months of operating life
See more

Particulate Matter

Reliable information about particulate matter

GASPLUG TECHNOLOGY | PATENTED DESIGN

Specs

  • Optical particle counter
  • Up to R2 >0.9
  • Range: 0-1,000 | 0-2,000 | 0-10,000 ppb
  • Resolution: 1 μg/m3
  • 24 months of operating life
See more