Case Study

Meteorological parameters and air quality sensor network in Alaquàs

Alaquàs town hall
Sector:

Need

This air quality monitoring network in Alaquàs (Valencia) provides the town with information on atmospheric and meteorological variables. To achieve this objective, fixed sensors have been installed at various points in the population. The integration and sending of data are done via Rest API to the city’s Smart City platform. All this deployment is developed within the “Environmental Monitoring System Project” (Smart Cities 2019 of the Valencia Provincial Council).

Alaquàs City Council needed an autonomous air quality monitoring system capable of providing air pollution and weather values. The aim was for the municipality to have its own management resources. The solution adopted consisted of its own monitoring system using a network of air quality sensors. Thus, with the provision of infrastructure and resources, it is now possible to record data on the concentration of gaseous pollutants and particulate matter. In this way, in addition to strengthening local capacities, the measurement and monitoring systems of the supra-municipal bodies are also complemented.

Creation of an air quality monitoring network to record data on the concentration of pollutant gases and suspended particles.

Solution

Deployment of a network of Kunak AIR stations with wireless communications to monitor pollutant gases and particulate matter. One of the devices has a weather station (anemometer and rain gauge) that continuously records climate parameters.

The Kunak AIR Cloud platform allows remote configuration and updating of the devices, as well as visualisation and analysis of the climatic parameters of the air measured by the equipment.

In addition, these recorded data will be sent to the SENTILO platform of the Valencia Provincial Council.

Completed actions:

  • Deployment of a sensor network with embedded wireless communications.
  • Development of an API for integration into the client’s server.
  • System of warnings for failures and alerts for high concentration.
  • Data analysis for the implementation of improvement plans.
  • Mobile application.

Results

We developed an environmental monitoring solution with the following functionalities:

  • Alarm system, alerts and statistics in real-time.
  • Detection of episodes of increased pollution.
  • Remote management and calibration of equipment.
  • Development of advanced statistical protocols for obtaining high-quality and reliable data that provide high correlations with official stations and reference equipment.

Project details

Customer: Alaquàs town hall

User: Alaquàs town hall

Location: Alaquàs, Spain

Sector:

Year: 2020

Parameters:

  • CO, NO, NO2 and O3.
  • Particles PM1, PM2.5 and PM10.
  • Temperature, relative humidity and atmospheric pressure
  • Precipitation.
  • Wind speed and direction.

Solutions

  • AIR ProProfessional air quality monitoring station
    Air quality monitor

    AIR Pro

    The most accurate air quality monitoring station

    SENSOR-BASED | BEST AVAILABLE ACCURACY

    Benefits

    • Multi-pollutant
    • Smart cartridge system
    • Fully autonomous
    • Real-time data
    • Proven accuracy
    See more
  • AIR CloudAir quality software
    Air quality software - Kunak AIR Cloud

    AIR Cloud

    Multipurpose air quality software for professionals

    REAL-TIME DATA | ALWAYS UPDATED

    Benefits

    • Secure and condifential
    • Air quality reporting
    • Advanced data analysis and visualisation
    • Reliable data guaranteed
    • Data sharing and integration
    See more
  • Carbon monoxideReliable real-time data on CO
    Carbon-monoxide

    Carbon monoxide

    Reliable information about carbon monoxide

    GASPLUG TECHNOLOGY | PATENTED DESIGN

    Specs

    • Electrochemical
    • R2 >0.85
    • Range: 0-12,000 ppb (Type A) | 0-500 ppm (Type B)
    • Resolution: 1 ppb (Type A) | 0.01 ppm (Type B)
    • 24 months of operating life
    See more
  • Nitric oxideReliable real-time data on NO
    Nitric_oxide_cartucho

    Nitric oxide

    Reliable information about nitric oxide

    GASPLUG TECHNOLOGY | PATENTED DESIGN

    Specs

    • Electrochemical
    • R2 >0.9
    • Range: 0-5,000 ppb
    • Resolution: 1 ppb
    • 24 months of operating life
    See more
  • Nitrogen dioxideReliable real-time data on NO2
    Nitreogen_dioxide

    Nitrogen dioxide

    Reliable information about nitrogen dioxide

    GASPLUG TECHNOLOGY | PATENTED DESIGN

    Specs

    • Electrochemical
    • R2 >0.85
    • Range: 0-12,000 ppb (Type A) | 0-500 ppm (Type B)
    • Resolution: 1 ppb (Type A) | 0.01 ppm (Type B)
    • 24 months of operating life
    See more
  • OzoneReliable real-time data on O3
    Ozone

    Ozone

    Reliable information about ozone

    GASPLUG TECHNOLOGY | PATENTED DESIGN

    Specs

    • Electrochemical
    • R2 >0.9
    • Range: 0-2,000 ppb
    • Resolution: 1 ppb
    • 24 months of operating life
    See more
  • Particulate MatterReliable real-time data on suspended particles

    Particulate Matter

    Reliable information about particulate matter

    GASPLUG TECHNOLOGY | PATENTED DESIGN

    Specs

    • Optical particle counter
    • Up to R2 >0.9
    • Range: 0-1,000 | 0-2,000 | 0-10,000 ppb
    • Resolution: 1 μg/m3
    • 24 months of operating life
    See more
Air quality monitor

AIR Pro

The most accurate air quality monitoring station

SENSOR-BASED | BEST AVAILABLE ACCURACY

Benefits

  • Multi-pollutant
  • Smart cartridge system
  • Fully autonomous
  • Real-time data
  • Proven accuracy
See more
Air quality software - Kunak AIR Cloud

AIR Cloud

Multipurpose air quality software for professionals

REAL-TIME DATA | ALWAYS UPDATED

Benefits

  • Secure and condifential
  • Air quality reporting
  • Advanced data analysis and visualisation
  • Reliable data guaranteed
  • Data sharing and integration
See more
Carbon-monoxide

Carbon monoxide

Reliable information about carbon monoxide

GASPLUG TECHNOLOGY | PATENTED DESIGN

Specs

  • Electrochemical
  • R2 >0.85
  • Range: 0-12,000 ppb (Type A) | 0-500 ppm (Type B)
  • Resolution: 1 ppb (Type A) | 0.01 ppm (Type B)
  • 24 months of operating life
See more
Nitric_oxide_cartucho

Nitric oxide

Reliable information about nitric oxide

GASPLUG TECHNOLOGY | PATENTED DESIGN

Specs

  • Electrochemical
  • R2 >0.9
  • Range: 0-5,000 ppb
  • Resolution: 1 ppb
  • 24 months of operating life
See more
Nitreogen_dioxide

Nitrogen dioxide

Reliable information about nitrogen dioxide

GASPLUG TECHNOLOGY | PATENTED DESIGN

Specs

  • Electrochemical
  • R2 >0.85
  • Range: 0-12,000 ppb (Type A) | 0-500 ppm (Type B)
  • Resolution: 1 ppb (Type A) | 0.01 ppm (Type B)
  • 24 months of operating life
See more
Ozone

Ozone

Reliable information about ozone

GASPLUG TECHNOLOGY | PATENTED DESIGN

Specs

  • Electrochemical
  • R2 >0.9
  • Range: 0-2,000 ppb
  • Resolution: 1 ppb
  • 24 months of operating life
See more

Particulate Matter

Reliable information about particulate matter

GASPLUG TECHNOLOGY | PATENTED DESIGN

Specs

  • Optical particle counter
  • Up to R2 >0.9
  • Range: 0-1,000 | 0-2,000 | 0-10,000 ppb
  • Resolution: 1 μg/m3
  • 24 months of operating life
See more