Accesories
Air quality sensor accessories – more data for better decisions
Want to get the most data about air pollution?

ACCESORIES
Product information
Air quality sensor accessories maximise the performance of our Kunak AIR stations.
Attached externally to the device, they collect and provide:
- Meteorological and atmospheric information (wind direction and speed, precipitation, heat stress, solar radiation, UV-A ultraviolet radiation, etc.)
- Energy independence, thanks to the internal battery with which the stations are equipped and the possibility of connecting a solar panel. The Kunak AIR units can also be connected to mains electricity.
These accessories for air quality sensors turn our solutions into all-terrain devices capable of monitoring atmospheric conditions in remote areas with no or irregular power supply.
The collection of meteorological variables also makes it possible to analyse the impact of the weather on the concentration or immission levels of various pollutants.
Power packs
Kunak AIR stations are equipped with a rechargeable lithium battery which prevents the equipment from shutting down due to a power cut. In this way, they can continue working for long periods of time until the power is restored.
Different power packs are available to power the devices.

Solar panel
The high-efficiency monocrystalline solar panel is robust, waterproof (IP67) and has been designed for prolonged outdoor use in any environment. The photovoltaic panel makes the device autonomous from the power grid, allowing the installation anywhere without civil works or in remote locations. All solar panel models include a mounting kit.
Power | Dimensions | Weight | Installation notes |
6W | 320 x 190 x 110 mm | 1.250 kg | Air Lite: between 0-50ºN/S parallels |
12W | 340 x 220 x 110 mm | 2.350 kg | AIR Pro: between the 0-50ºN/S parallels AIR Lite: above the 50ºN/S parallels |
26W | 450 x 350 x 110 mm | 3.150 kg | Above the 50ºN/S parallels |
Dimensions without box. Each solar panel ensures sufficient power supply depending on the application and project location. |

Outdoor charger
An outdoor charger must be used when the Kunak AIR station is going to be installed outdoors. It is small, lightweight, waterproof (IP67) and has been designed for prolonged outdoor use in any environment. AC cable not included.
Dimensions | Weight | Input voltage | Output voltage |
200 x 85 x 95 mm | 750 gr | 100-240V AC 50-60 Hz | 12V DC |

Indoor Charger
An indoor charger with global plugs is available for testing and verification. Not for outdoor use. Only available with the purchase of a power pack.
Dimensions | Weight | Input voltage | Output voltage |
75 x 35.8 x 65.6 mm | 170 gr | 100-240V AC 50-60 Hz | 9V DC |
Meteo sensors

Mechanical anemometer
Wind speed range | 0.5 to 89 m/s |
---|---|
Wind speed resolution | 0.5 m/s |
Wind speed accuracy | ± 1 m/s or ± 5% |
Direction resolution | 1º on compass rose |
Direction accuracy | ± 3º |
Operating temperature | -40ºC to 65ºC |
Weight | 1.3 kg |
Dimensions | 381 x 38 x 457 mm |

Ultrasonic anemometer
- Max. wind speed
- Average wind speed
- Wind direction
Wind speed range | 0.13 to 40 m/s |
---|---|
Wind speed resolution | 0.05 m/s |
Wind speed accuracy | 0.12 m/s |
Weight | 0.2kg |
Direction resolution | 1º |
Direction accuracy | ± 1.5º |
Operating temperature | -15ºC to 55ºC |
Dimensions | 300 x Ø16 mm |

Rain gauge
Typical accuracy | ±0.2 mm |
---|---|
Resolution | 0.2 mm |
Weight | 0.5 kg |
Operating temperature | 0 ºC to 60 ºC |
Orifice area | Ø200 cm² |
Dimensions | 255 x Ø165 mm |

Sound level meter
Measuring range | 40-130 dB(A) 20 - 12,500 Hz |
---|---|
Operating temperature | -10 to 50 ºC |
Weight | 2.5 kg |
Resolution | 0.1 dB |
Typical accuracy | ±1 dB(A) |
Dimensions | 191 x 296 x 168 mm |

Pyranometer
Range | 0 to 1600 W/m² 285 to 3000 nm |
---|---|
Typical accuracy | ± 0.2 W/m² |
Weight | 0.5 kg |
Resolution | 0.2 W/m² |
Operating temperature | -40 to 80 ºC |
Dimensions | Ø56 x 70 mm |
Protocol | Modbus RTU (RS-485) |

Radiation sensor
Range | 0 to 200 W/m² 280 to 400 nm |
---|---|
Accuracy | ±5% rdg |
Weight | 150 g |
Response time | ≤1s |
Operating temperature | -40 to 85 ºC |
Dimensions | Ø64 x 33.5 mm |
Protocol | Modbus RTU (RS-485) |

Wet Bulb Globe Thermometer (WBGT)
Range | -40 to 80 ºC |
---|---|
Accuracy (0°C to 60°C) | ±0.2 ºC |
Weight | 780 g |
Resolution | 0.05 ºC |
Operating temperature | -40 to 60 ºC |
Dimensions | 15 x 15 x 25.9 cm |
Protocol | Modbus RTU (RS-485) |

Gashood