{"id":67797,"date":"2026-04-13T15:29:36","date_gmt":"2026-04-13T13:29:36","guid":{"rendered":"https:\/\/kunakair.com\/?p=67797"},"modified":"2026-04-14T17:28:22","modified_gmt":"2026-04-14T15:28:22","slug":"medicion-de-pm10-en-entornos-con-alta-presencia-de-particulas-gruesas","status":"publish","type":"post","link":"https:\/\/kunakair.com\/es\/medicion-de-pm10-en-entornos-con-alta-presencia-de-particulas-gruesas\/","title":{"rendered":"Medici\u00f3n de PM<sub>10<\/sub> en entornos con alta presencia de part\u00edculas gruesas: por qu\u00e9 importa la tecnolog\u00eda del sensor"},"content":{"rendered":"<h2>Contexto<\/h2>\n<p>El material particulado (PM) no es un \u00fanico contaminante, sino una mezcla de part\u00edculas de distintos tama\u00f1os, composiciones y or\u00edgenes. El tama\u00f1o de estas part\u00edculas determina cu\u00e1nto tiempo permanecen suspendidas en el aire y hasta qu\u00e9 punto penetran en el sistema respiratorio humano.<\/p>\n<p>Para fines regulatorios y de monitorizaci\u00f3n ambiental, dos fracciones son especialmente relevantes:<\/p>\n<ul>\n<li><strong>PM<sub>2.5<\/sub><\/strong>: part\u00edculas con un di\u00e1metro inferior a 2,5 \u00b5m, normalmente asociadas a procesos de combusti\u00f3n.<\/li>\n<li><strong>PM<sub>10<\/sub><\/strong>: part\u00edculas con un di\u00e1metro inferior a 10 \u00b5m, que incluyen tanto part\u00edculas finas (PM<sub>2.5<\/sub>) como part\u00edculas gruesas (PM<sub>2.5\u201310<\/sub>).<\/li>\n<\/ul>\n<p>Distinguir correctamente entre <strong>part\u00edculas finas (PM<sub>2.5<\/sub>)<\/strong> y <strong>part\u00edculas gruesas (PM<sub>2.5-10<\/sub>)<\/strong> es esencial, ya que estas fracciones proceden de fuentes diferentes, tienen mecanismos de transporte distintos y presentan efectos claramente diferentes sobre la salud y el medio ambiente.<\/p>\n<p>En particular, la presencia de <strong>part\u00edculas gruesas<\/strong> est\u00e1 fuertemente asociada a procesos mec\u00e1nicos, como el movimiento de tierras, la manipulaci\u00f3n de materiales, el tr\u00e1fico sobre superficies no pavimentadas, la actividad minera, las operaciones portuarias, las actividades agr\u00edcolas o los trabajos de construcci\u00f3n y demolici\u00f3n. Estos entornos pueden generar altas concentraciones de part\u00edculas en el rango de 2,5 a 10 \u00b5m, lo que hace que la <strong>cuantificaci\u00f3n precisa de PM<sub>10<\/sub> sea especialmente exigente<\/strong>.<\/p>\n<h2>Tipos de sensores PM de bajo coste<\/h2>\n<p>En los \u00faltimos a\u00f1os, los sensores PM de bajo coste se han extendido ampliamente. Sin embargo, no todos los sensores miden PM<sub>10<\/sub> de la misma manera.<\/p>\n<p>De forma general, existen dos enfoques t\u00e9cnicos:<\/p>\n<h3>Sensores que estiman PM<sub>10<\/sub> a partir de PM<sub>2.5<\/sub><\/h3>\n<p>Algunos sensores \u00f3pticos est\u00e1n optimizados principalmente para la detecci\u00f3n de part\u00edculas finas. Estos sensores aplican relaciones fijas entre tama\u00f1os de part\u00edcula para extrapolar PM<sub>10<\/sub> a partir de los valores medidos de PM<sub>2.5<\/sub>. En estos casos, <strong>PM<sub>10<\/sub> no se mide directamente<\/strong>, sino que se infiere a partir de distribuciones de part\u00edculas asumidas.<\/p>\n<p>Este enfoque puede funcionar razonablemente bien en entornos urbanos dominados por part\u00edculas finas, pero puede introducir sesgos importantes en entornos donde predominan las part\u00edculas gruesas.<\/p>\n<h3>Sensores basados en tecnolog\u00eda OPC<\/h3>\n<p>La tecnolog\u00eda <strong>Optical Particle Counter (OPC)<\/strong>, como el que incorpora el Kunak AIR Pro, utiliza la dispersi\u00f3n de luz l\u00e1ser para detectar y clasificar individualmente las part\u00edculas en m\u00faltiples rangos de di\u00e1metro.<\/p>\n<p>Las principales caracter\u00edsticas de un sensor OPC son:<\/p>\n<ul>\n<li>Mide en un rango de tama\u00f1os ampliado, por encima de 10 \u00b5m.<\/li>\n<li>Incluye suficientes canales de tama\u00f1o para resolver distribuciones de part\u00edculas.<\/li>\n<\/ul>\n<div class=\"kunak-cita-destacada\">Este tipo de sensores puede cuantificar directamente las fracciones gruesas y calcular PM<sub>10<\/sub> a partir de distribuciones de tama\u00f1o realmente medidas.<\/div>\n<p>Esto permite una discriminaci\u00f3n real por tama\u00f1o de part\u00edcula, la detecci\u00f3n de la fracci\u00f3n gruesa y el c\u00e1lculo directo de PM<sub>10<\/sub> sin depender de relaciones asumidas.<\/p>\n<p>En entornos con alta presencia de part\u00edculas gruesas, esta diferencia es cr\u00edtica.<\/p>\n<h2>Objetivo de este estudio<\/h2>\n<p>Este art\u00edculo presenta resultados de validaci\u00f3n en campo del sensor PM de Kunak AIR Pro en condiciones con concentraciones elevadas de part\u00edculas gruesas.<\/p>\n<p>Los resultados demuestran que el sensor mantiene una alta precisi\u00f3n y una buena concordancia con instrumentaci\u00f3n equivalente en la medici\u00f3n de PM<sub>10<\/sub>, incluso en entornos donde predominan las part\u00edculas gruesas.<\/p>\n<p>Estos hallazgos confirman la idoneidad del sensor PM de Kunak para aplicaciones regulatorias, industriales, urbanas y ocupacionales en las que disponer de datos fiables de PM<sub>10<\/sub> es esencial para el cumplimiento ambiental, el control operativo y la protecci\u00f3n de la salud p\u00fablica.<\/p>\n<h2>Kunak AIR Pro, sensor PM<\/h2>\n<p>El sensor PM de Kunak est\u00e1 basado en tecnolog\u00eda de dispersi\u00f3n de luz l\u00e1ser y est\u00e1 certificado dentro de <a target=\"_blank\" href=\"https:\/\/kunakair.com\/es\/kunak-air-pro-certificado-mcerts\/\"><strong>MCERTS Certified Products: Indicative Ambient Particulate Monitors<\/strong><\/a> para PM<sub>10<\/sub> y PM<sub>2.5<\/sub>. Tambi\u00e9n cuenta con la <a target=\"_blank\" href=\"https:\/\/kunakair.com\/es\/kunak-air-pro-certificacion-grado-1-pm2-5-corea-del-sur\/\"><strong>certificaci\u00f3n KOTITI Grade 1 para PM<sub>2.5<\/sub><\/strong><\/a>, lo que refuerza su rendimiento y fiabilidad de medici\u00f3n.<\/p>\n<p>Las estaciones <a target=\"_blank\" href=\"https:\/\/kunakair.com\/es\/air-quality-monitor-2\/\">Kunak AIR Pro<\/a> integran un OPC capaz de medir part\u00edculas desde 0,3 \u03bcm hasta 40 \u03bcm gracias a 24 canales bin.<\/p>\n<p>PM<sub>1<\/sub>, PM<sub>2.5<\/sub>, PM<sub>4<\/sub>, PM<sub>10<\/sub>, part\u00edculas totales en suspensi\u00f3n (TSP) y contador total de part\u00edculas (TPC) se calculan asumiendo un perfil de densidad de part\u00edculas.<\/p>\n<p>Los estudios de coubicaci\u00f3n en campo han <strong>mostrado un rendimiento similar al de instrumentos equivalentes<\/strong> basados en la misma tecnolog\u00eda, incluso en la monitorizaci\u00f3n de part\u00edculas gruesas.<\/p>\n<p>El efecto de la humedad se corrige mediante el algoritmo integrado, alcanzando una alta precisi\u00f3n en cualquier condici\u00f3n ambiental, salvo en d\u00edas con niebla o condensaci\u00f3n, en los que los datos se invalidan autom\u00e1ticamente desde Kunak AIR Cloud para evitar ruido.<\/p>\n<p>Adem\u00e1s, la herramienta de calibraci\u00f3n remota de Kunak permite ajustar el factor de correcci\u00f3n a la ubicaci\u00f3n espec\u00edfica donde se instala el dispositivo.<\/p>\n<div id=\"attachment_67674\" style=\"width: 1547px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-67674\" class=\"wp-image-67674 size-full\" src=\"https:\/\/kunakair.com\/wp-content\/uploads\/2026\/03\/kunak-air-pro-pm-sensor.jpg\" alt=\"Kunak AIR Pro: sensor profesional de part\u00edculas para medir PM&lt;sub&gt;1&lt;\/sub&gt;, PM&lt;sub&gt;2,5&lt;\/sub&gt;, PM&lt;sub&gt;4&lt;\/sub&gt;, PM&lt;sub&gt;10&lt;\/sub&gt;, part\u00edculas suspendidas totales (TSP) y contador de part\u00edculas totales (TPC)\" width=\"1537\" height=\"863\" srcset=\"https:\/\/kunakair.com\/wp-content\/uploads\/2026\/03\/kunak-air-pro-pm-sensor.jpg 1537w, https:\/\/kunakair.com\/wp-content\/uploads\/2026\/03\/kunak-air-pro-pm-sensor-1280x719.jpg 1280w, https:\/\/kunakair.com\/wp-content\/uploads\/2026\/03\/kunak-air-pro-pm-sensor-980x550.jpg 980w, https:\/\/kunakair.com\/wp-content\/uploads\/2026\/03\/kunak-air-pro-pm-sensor-480x270.jpg 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) and (max-width: 1280px) 1280px, (min-width: 1281px) 1537px, 100vw\" \/><p id=\"caption-attachment-67674\" class=\"wp-caption-text\">Kunak AIR Pro: sensor profesional de part\u00edculas para medir PM<sub>1<\/sub>, PM<sub>2,5<\/sub>, PM<sub>4<\/sub>, PM<sub>10<\/sub>, part\u00edculas suspendidas totales (TSP) y contador de part\u00edculas totales (TPC)<\/p><\/div>\n<p>&nbsp;<\/p>\n<div id=\"attachment_67675\" style=\"width: 1556px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-67675\" class=\"wp-image-67675 size-full\" src=\"https:\/\/kunakair.com\/wp-content\/uploads\/2026\/03\/kunak-air-pro-pm-monitoring.jpg\" alt=\"Imagen renderizada del OPC (contador \u00f3ptico de part\u00edculas) del Kunak AIR Pro\" width=\"1546\" height=\"857\" srcset=\"https:\/\/kunakair.com\/wp-content\/uploads\/2026\/03\/kunak-air-pro-pm-monitoring.jpg 1546w, https:\/\/kunakair.com\/wp-content\/uploads\/2026\/03\/kunak-air-pro-pm-monitoring-1280x710.jpg 1280w, https:\/\/kunakair.com\/wp-content\/uploads\/2026\/03\/kunak-air-pro-pm-monitoring-980x543.jpg 980w, https:\/\/kunakair.com\/wp-content\/uploads\/2026\/03\/kunak-air-pro-pm-monitoring-480x266.jpg 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) and (max-width: 1280px) 1280px, (min-width: 1281px) 1546px, 100vw\" \/><p id=\"caption-attachment-67675\" class=\"wp-caption-text\">Imagen renderizada del OPC (contador \u00f3ptico de part\u00edculas) del Kunak AIR Pro<\/p><\/div>\n<p>&nbsp;<\/p>\n<h3>Especificaciones del sensor de PM tipo A (solo para Kunak AIR Pro)<\/h3>\n<table width=\"100%\">\n<tbody>\n<tr>\n<td style=\"width: 17%;\"><strong>Tipo<\/strong><\/td>\n<td style=\"width: 33%;\">Contador \u00f3ptico de part\u00edculas<\/td>\n<td style=\"width: 17%;\"><strong>Repetibilidad <sup>(9)<\/sup><\/strong><\/td>\n<td style=\"width: 33%;\">2 \u00b5g\/m<sup>3<\/sup> (PM<sub>1<\/sub>) 3 \u00b5g\/m<sup>3<\/sup> (PM<sub>2.5<\/sub>) 3 \u00b5g\/m<sup>3<\/sup> (PM<sub>4<\/sub>) 5 \u00b5g\/m<sup>3<\/sup> (PM<sub>10<\/sub>) 6 \u00b5g\/m<sup>3<\/sup> (TSP)<\/td>\n<\/tr>\n<tr>\n<td><strong>Unidad de medida<\/strong><\/td>\n<td>\u00b5g\/m<sup>3<\/sup><\/td>\n<td><strong>L\u00edmite de detecci\u00f3n (LOD) <sup>(8)<\/sup><\/strong><\/td>\n<td>0.5 \u00b5g\/m<sup>3<\/sup> (PM<sub>1<\/sub>) 0.5 \u00b5g\/m<sup>3<\/sup> (PM<sub>2.5<\/sub>) 0.5 \u00b5g\/m<sup>3<\/sup> (PM<sub>4<\/sub>) 1 \u00b5g\/m<sup>3<\/sup> (PM<sub>10<\/sub>) 1 \u00b5g\/m<sup>3<\/sup> (TSP)<\/td>\n<\/tr>\n<tr>\n<td><strong>Rango de medida <sup>(1)<\/sup><\/strong><\/td>\n<td>0 &#8211; 1,000 \u00b5g\/m<sup>3<\/sup> (PM<sub>1<\/sub>) 0 &#8211; 2,000 \u00b5g\/m<sup>3<\/sup> (PM<sub>2.5<\/sub>) 0 &#8211; 2,000 \u00b5g\/m<sup>3<\/sup> (PM<sub>4<\/sub>) 0 &#8211; 10,000 \u00b5g\/m<sup>3<\/sup> (PM<sub>10<\/sub>) 0 &#8211; 15,000 \u00b5g\/m<sup>3<\/sup> (TSP) 0 &#8211; 8,000 counts\/cm<sup>3<\/sup> (TPC)<\/td>\n<td><strong>Precisi\u00f3n t\u00edpica <sup>(12)<\/sup><\/strong><\/td>\n<td>\u00b1 2 \u00b5g\/m<sup>3<\/sup> (PM<sub>1<\/sub>) \u00b1 3 \u00b5g\/m<sup>3<\/sup> (PM<sub>2.5<\/sub>) \u00b1 3 \u00b5g\/m<sup>3<\/sup> (PM<sub>4<\/sub>) \u00b1 4 \u00b5g\/m<sup>3<\/sup> (PM<sub>10<\/sub>) \u00b1 6 \u00b5g\/m<sup>3<\/sup> (TSP)<\/td>\n<\/tr>\n<tr>\n<td><strong>Resoluci\u00f3n <sup>(2)<\/sup><\/strong><\/td>\n<td>1 \u00b5g\/m<sup>3<\/sup> 1 count\/cm<sup>3<\/sup> (TPC)<\/td>\n<td><strong>Precisi\u00f3n t\u00edpica &#8211; R<sup>2<\/sup> <sup>(11)<\/sup><\/strong><\/td>\n<td>&gt; 0.9 (PM<sub>1<\/sub>) &gt; 0.8 (PM<sub>2.5<\/sub>) &gt; 0.8 (PM<sub>4<\/sub>) &gt; 0.7 (PM<sub>10<\/sub>) &gt; 0.7 (TSP) &gt; 0.8 (TPC)<\/td>\n<\/tr>\n<tr>\n<td><strong>Rango de temperatura de funcionamiento <sup>(3)<\/sup><\/strong><\/td>\n<td>-20 a 50 \u00b0C -40 a 50 \u00b0C con calentador **<\/td>\n<td><strong>Pendiente t\u00edpica <sup>(11)<\/sup><\/strong><\/td>\n<td>0.85 &#8211; 1.18<\/td>\n<\/tr>\n<tr>\n<td><strong>Rango de HR de funcionamiento <sup>(4)<\/sup><\/strong><\/td>\n<td>0 a 99 %RH<\/td>\n<td><strong>Intercepto t\u00edpico (a) <sup>(11)<\/sup><\/strong><\/td>\n<td>-1.8 \u00b5g\/m<sup>3<\/sup> \u2264 a \u2264 +1.8 \u00b5g\/m<sup>3<\/sup> (PM<sub>1<\/sub>) -2 \u00b5g\/m<sup>3<\/sup> \u2264 a \u2264 +2 \u00b5g\/m<sup>3<\/sup> (PM<sub>2.5<\/sub>) -2 \u00b5g\/m<sup>3<\/sup> \u2264 a \u2264 +2 \u00b5g\/m<sup>3<\/sup> (PM<sub>4<\/sub>) -3 \u00b5g\/m<sup>3<\/sup> \u2264 a \u2264 +3 \u00b5g\/m<sup>3<\/sup> (PM<sub>10<\/sub>) -4 \u00b5g\/m<sup>3<\/sup> \u2264 a \u2264 +4 \u00b5g\/m<sup>3<\/sup> (TSP)<\/td>\n<\/tr>\n<tr>\n<td><strong>Rango de HR recomendado <sup>(5)<\/sup><\/strong><\/td>\n<td>0 a 95 %RH<\/td>\n<td><strong>DQO &#8211; U(exp) t\u00edpica <sup>(13)<\/sup><\/strong><\/td>\n<td>&lt; 50% (PM<sub>1<\/sub> &#8211; PM<sub>4<\/sub> &#8211; PM<sub>10<\/sub> &#8211; TSP) &lt; 35% (PM<sub>2.5<\/sub>)<\/td>\n<\/tr>\n<tr>\n<td><strong>Vida \u00fatil <sup>(6)<\/sup><\/strong><\/td>\n<td>&gt; 24 meses<\/td>\n<td><strong>Variabilidad intramodelo t\u00edpica <sup>(14)<\/sup><\/strong><\/td>\n<td>&lt; 2 \u00b5g\/m<sup>3<\/sup><\/td>\n<\/tr>\n<tr>\n<td><strong>Tiempo de respuesta <sup>(10)<\/sup><\/strong><\/td>\n<td>&lt; 10 s<\/td>\n<td colspan=\"2\"><\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\"><span style=\"font-size: 8pt;\">1. Rango de medida: rango de concentraci\u00f3n medido por el sensor.<br \/>\n2. Resoluci\u00f3n: unidad m\u00e1s peque\u00f1a de medida que puede indicar el sensor.<br \/>\n3. Rango de temperatura de funcionamiento: intervalo de temperatura en el que el sensor puede operar con seguridad y proporcionar mediciones. (**) En el sensor PM Tipo A: -40 a 50\u00baC con calentador (m\u00e1s informaci\u00f3n sobre esta versi\u00f3n bajo solicitud).<br \/>\n4. Rango de HR de funcionamiento: intervalo de humedad en el que el sensor puede operar con seguridad y proporcionar mediciones.<br \/>\n5. Rango de HR recomendado: rango de humedad relativa recomendado para un rendimiento \u00f3ptimo del sensor. La exposici\u00f3n continua fuera del rango recomendado puede da\u00f1ar el cartucho.<br \/>\n6. Vida \u00fatil: periodo durante el cual el sensor puede operar de forma eficaz y precisa en condiciones normales.<br \/>\n7. Rango de garant\u00eda: rango de concentraci\u00f3n cubierto por la garant\u00eda de Kunak.<br \/>\n8. LOD (l\u00edmite de detecci\u00f3n): medido en condiciones de laboratorio a 20\u00baC y 50% HR. El l\u00edmite de detecci\u00f3n es la concentraci\u00f3n m\u00ednima que puede detectarse como significativamente diferente de la concentraci\u00f3n cero de gas, calculada seg\u00fan la especificaci\u00f3n t\u00e9cnica CEN\/TS 17660.<br \/>\n9. Repetibilidad: medida en condiciones de laboratorio a 20\u00baC y 50% HR. Grado de concordancia entre los resultados de mediciones sucesivas de la misma magnitud realizadas bajo las mismas condiciones de medida, calculado seg\u00fan la especificaci\u00f3n t\u00e9cnica CEN\/TS 17660.<br \/>\n10. Tiempo de respuesta: tiempo necesario para que el sensor alcance el 90% del valor final estable.<br \/>\n11. Precisi\u00f3n t\u00edpica &#8211; R2: estad\u00edsticas obtenidas entre las mediciones horarias del dispositivo y los instrumentos de referencia en ensayos de campo entre -10 y +30\u00baC en distintas ubicaciones. (*) En el sensor PM tipo B, el error esperado para PM 10 es mayor en presencia de part\u00edculas gruesas.<br \/>\n12. Precisi\u00f3n t\u00edpica: para contaminantes criterio es el error absoluto medio (MAE) obtenido entre las mediciones horarias del dispositivo y los instrumentos de referencia en ensayos de campo de 1 a 8 meses entre -10 y +30\u00baC en distintos pa\u00edses. Para otros contaminantes es el error esperado de la medici\u00f3n en la lectura.<br \/>\n13. DQO &#8211; U(exp) t\u00edpica: objetivo de calidad de datos expresado como incertidumbre expandida en el valor l\u00edmite, obtenido entre las mediciones horarias del dispositivo y los instrumentos de referencia en ensayos de campo de 1 a 8 meses entre -10 y +30\u00baC en distintos pa\u00edses, calculado seg\u00fan la Directiva Europea de Calidad del Aire 2024\/2881 y la especificaci\u00f3n t\u00e9cnica CEN\/TS 17660. (*) En el sensor PM tipo B, el error esperado para PM 10 es mayor en presencia de part\u00edculas gruesas.<br \/>\n14. Variabilidad intramodelo t\u00edpica: calculada como la desviaci\u00f3n est\u00e1ndar de las medias de tres sensores en ensayos de campo de 1 a 8 meses entre -10 y +30\u00baC en distintos pa\u00edses.<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p>Adicionalmente, las gr\u00e1ficas de distribuci\u00f3n de tama\u00f1o de part\u00edculas tambi\u00e9n est\u00e1n disponibles en <a target=\"_blank\" href=\"https:\/\/kunakair.com\/es\/air-quality-software-2\/\">Kunak AIR Cloud<\/a>.<\/p>\n<div id=\"attachment_67677\" style=\"width: 1929px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-67677\" class=\"wp-image-67677 size-full\" src=\"https:\/\/kunakair.com\/wp-content\/uploads\/2026\/03\/PM-size-distribution-tool.jpg\" alt=\"Figura 1 - Herramienta de an\u00e1lisis del tama\u00f1o y la distribuci\u00f3n de las part\u00edculas\" width=\"1919\" height=\"1079\" srcset=\"https:\/\/kunakair.com\/wp-content\/uploads\/2026\/03\/PM-size-distribution-tool.jpg 1919w, https:\/\/kunakair.com\/wp-content\/uploads\/2026\/03\/PM-size-distribution-tool-1280x720.jpg 1280w, https:\/\/kunakair.com\/wp-content\/uploads\/2026\/03\/PM-size-distribution-tool-980x551.jpg 980w, https:\/\/kunakair.com\/wp-content\/uploads\/2026\/03\/PM-size-distribution-tool-480x270.jpg 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) and (max-width: 1280px) 1280px, (min-width: 1281px) 1919px, 100vw\" \/><p id=\"caption-attachment-67677\" class=\"wp-caption-text\">Figura 1. <br \/>Herramienta de an\u00e1lisis del tama\u00f1o y la distribuci\u00f3n de las part\u00edculas<\/p><\/div>\n<p>&nbsp;<\/p>\n<h2>Demostraci\u00f3n de precisi\u00f3n en mediciones de PM<sub>10<\/sub><\/h2>\n<h3>Procedimiento de an\u00e1lisis y caracterizaci\u00f3n<\/h3>\n<p>Las siguientes m\u00e9tricas y gr\u00e1ficos se utilizan para evaluar el rendimiento del sensor PM en el ensayo de campo.<\/p>\n<ul>\n<li><strong>Precisi\u00f3n<\/strong>: se obtiene como el error absoluto medio (MAE) entre las mediciones de KUNAKAIR y los instrumentos de referencia.<\/li>\n<li><strong>Intervalo de confianza del 90%<\/strong>: el 90% de las mediciones queda por debajo de ese error. Tambi\u00e9n se muestra el error relativo del error m\u00e1ximo dentro de ese 90%.<\/li>\n<li>Los resultados incluyen adem\u00e1s la concentraci\u00f3n media durante todo el ensayo.<\/li>\n<li><strong>Gr\u00e1ficas temporales, gr\u00e1ficas de dispersi\u00f3n y variaci\u00f3n temporal de la media<\/strong> se utilizan para analizar los resultados.<\/li>\n<\/ul>\n<h4>1. Ensayo de campo: Helsinki, Finlandia<\/h4>\n<ul>\n<li><strong>Ubicaci\u00f3n<\/strong>: Teollisuuskatu, Helsinki, Finlandia.<\/li>\n<li><strong>Periodo de ensayo<\/strong>: del 20 de febrero al 28 de abril de 2025.<\/li>\n<\/ul>\n<div style=\"display: flex; justify-content: center; margin: 20px 0;\">\n<div style=\"width: 100%; max-width: 50%;\">\n<p style=\"text-align: left; font-weight: bold; margin-bottom: 10px; color: #333;\">Tabla 1. Condiciones ambientales del ensayo de campo<\/p>\n<table style=\"border-collapse: collapse; width: 100%; background-color: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.1); border-radius: 8px; overflow: hidden;\">\n<thead>\n<tr style=\"background-color: #f8f9fa; border-bottom: 2px solid #eceeef;\">\n<th style=\"padding: 12px; text-align: left; color: #495057;\">Par\u00e1metro<\/th>\n<th style=\"padding: 12px; text-align: center; color: #495057;\">M\u00edn.<\/th>\n<th style=\"padding: 12px; text-align: center; color: #495057;\">Media<\/th>\n<th style=\"padding: 12px; text-align: center; color: #495057;\">M\u00e1x.<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr style=\"border-bottom: 1px solid #eceeef;\">\n<td style=\"padding: 12px; font-weight: bold; color: #333;\">T (\u00b0C)<\/td>\n<td style=\"padding: 12px; text-align: center;\">-8.36<\/td>\n<td style=\"padding: 12px; text-align: center;\">4.17<\/td>\n<td style=\"padding: 12px; text-align: center;\">19.46<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 12px; font-weight: bold; color: #333;\">HR (%)<\/td>\n<td style=\"padding: 12px; text-align: center;\">21.01<\/td>\n<td style=\"padding: 12px; text-align: center;\">70.58<\/td>\n<td style=\"padding: 12px; text-align: center;\">95.58<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<div style=\"display: flex; justify-content: center; margin: 20px 0;\">\n<div style=\"width: 100%; max-width: 70%;\">\n<p style=\"text-align: left; font-weight: bold; margin-bottom: 10px; color: #333;\">Tabla 2. Estad\u00edsticas de PM<sub>2.5<\/sub> y PM<sub>10<\/sub> medidas por la estaci\u00f3n de monitorizaci\u00f3n de la calidad del aire (Referencia)<\/p>\n<table style=\"border-collapse: collapse; width: 100%; background-color: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.1); border-radius: 8px; overflow: hidden;\">\n<thead>\n<tr style=\"background-color: #f8f9fa; border-bottom: 2px solid #eceeef;\">\n<th style=\"padding: 12px; text-align: left; color: #495057;\">Estaci\u00f3n<\/th>\n<th style=\"padding: 12px; text-align: left; color: #495057;\">Sensor<\/th>\n<th style=\"padding: 12px; text-align: center; color: #495057;\">Media<\/th>\n<th style=\"padding: 12px; text-align: center; color: #495057;\">M\u00e1ximo<\/th>\n<th style=\"padding: 12px; text-align: center; color: #495057;\">M\u00ednimo<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr style=\"border-bottom: 1px solid #eceeef;\">\n<td style=\"padding: 12px; font-weight: bold; color: #333; vertical-align: middle; border-right: 1px solid #eceeef;\" rowspan=\"2\">RS Helsinki Teollisuuskatu<\/td>\n<td style=\"padding: 12px; color: #555;\">PM<sub>2.5<\/sub> (\u00b5g\/m<sup>3<\/sup>)<\/td>\n<td style=\"padding: 12px; text-align: center;\">10.66<\/td>\n<td style=\"padding: 12px; text-align: center;\">78.1<\/td>\n<td style=\"padding: 12px; text-align: center;\">0.4<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 12px; color: #555;\">PM<sub>10<\/sub> (\u00b5g\/m<sup>3<\/sup>)<\/td>\n<td style=\"padding: 12px; text-align: center;\">32.37<\/td>\n<td style=\"padding: 12px; text-align: center;\">386.1<\/td>\n<td style=\"padding: 12px; text-align: center;\">2.1<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<p>La Figura 2 muestra c\u00f3mo la concentraci\u00f3n de PM<sub>10<\/sub> es superior a la de PM<sub>2.5<\/sub>, lo que demuestra la alta concentraci\u00f3n de part\u00edculas gruesas (PM<sub>10<\/sub> \u2013 PM<sub>2.5<\/sub>) monitorizadas durante el ensayo de campo.<\/p>\n<div id=\"attachment_67679\" style=\"width: 1133px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-67679\" class=\"wp-image-67679 size-full\" src=\"https:\/\/kunakair.com\/wp-content\/uploads\/2026\/03\/figure-2.jpg\" alt=\"\" width=\"1123\" height=\"395\" srcset=\"https:\/\/kunakair.com\/wp-content\/uploads\/2026\/03\/figure-2.jpg 1123w, https:\/\/kunakair.com\/wp-content\/uploads\/2026\/03\/figure-2-980x345.jpg 980w, https:\/\/kunakair.com\/wp-content\/uploads\/2026\/03\/figure-2-480x169.jpg 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1123px, 100vw\" \/><p id=\"caption-attachment-67679\" class=\"wp-caption-text\">Figura 2. <br \/>Gr\u00e1fica temporal de PM<sub>2.5<\/sub> y PM<sub>10<\/sub> de referencia.<\/p><\/div>\n<p>&nbsp;<\/p>\n<p>La siguiente figura (Figura 3) muestra la gr\u00e1fica temporal con las mediciones registradas por la estaci\u00f3n de referencia y los dos dispositivos Kunak. Como se observa, existen varios picos por encima del l\u00edmite de 190 \u00b5g\/m<sup>3<\/sup>. Adem\u00e1s, se aprecia c\u00f3mo las mediciones de PM<sub>10<\/sub> de Kunak est\u00e1n alineadas con las mediciones de PM<sub>10<\/sub> del analizador de part\u00edculas. La buena correlaci\u00f3n entre los dispositivos Kunak y los datos de referencia se muestra en la Figura 3, donde se presentan la gr\u00e1fica de dispersi\u00f3n, la correlaci\u00f3n (R<sup>2<\/sup>) y la ecuaci\u00f3n lineal. Ambos dispositivos muestran una correlaci\u00f3n elevada, superior a 0,80, con una pendiente cercana a 1 y un peque\u00f1o offset (inferior a 2 \u00b5g\/m<sup>3<\/sup>).<\/p>\n<div id=\"attachment_67681\" style=\"width: 1142px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-67681\" class=\"wp-image-67681 size-full\" src=\"https:\/\/kunakair.com\/wp-content\/uploads\/2026\/03\/figure-3.jpg\" alt=\"Figura 3. Gr\u00e1fica temporal de los datos de referencia de PM&lt;sub&gt;10&lt;\/sub&gt; (verde) y de las mediciones de PM&lt;sub&gt;10&lt;\/sub&gt; de Kunak: dispositivos K-A3 RENT 1 (morado) y K-A3 RENT 4 (azul). La l\u00ednea roja muestra el l\u00edmite de concentraci\u00f3n de PM&lt;sub&gt;10&lt;\/sub&gt; de 190 \u00b5g\/m&lt;sup&gt;3&lt;\/sup&gt;.\" width=\"1132\" height=\"405\" srcset=\"https:\/\/kunakair.com\/wp-content\/uploads\/2026\/03\/figure-3.jpg 1132w, https:\/\/kunakair.com\/wp-content\/uploads\/2026\/03\/figure-3-980x351.jpg 980w, https:\/\/kunakair.com\/wp-content\/uploads\/2026\/03\/figure-3-480x172.jpg 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1132px, 100vw\" \/><p id=\"caption-attachment-67681\" class=\"wp-caption-text\">Figura 3. <br \/>Gr\u00e1fica temporal de los datos de referencia de PM<sub>10<\/sub> (verde) y de las mediciones de PM<sub>10<\/sub> de Kunak: dispositivos K-A3 RENT 1 (morado) y K-A3 RENT 4 (azul). La l\u00ednea roja muestra el l\u00edmite de concentraci\u00f3n de PM<sub>10<\/sub> de 190 \u00b5g\/m<sup>3<\/sup>.<\/p><\/div>\n<p>&nbsp;<\/p>\n<p>La Figura 4 muestra la gr\u00e1fica de variaci\u00f3n temporal, donde se observa c\u00f3mo los sensores PM de Kunak de ambos dispositivos siguen perfectamente las tendencias de PM<sub>10<\/sub> medidas por el instrumento equivalente.<\/p>\n<div id=\"attachment_67682\" style=\"width: 1619px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-67682\" class=\"wp-image-67682 size-full\" src=\"https:\/\/kunakair.com\/wp-content\/uploads\/2026\/03\/figure-4.jpg\" alt=\"Figura 4. Gr\u00e1fica de dispersi\u00f3n de los dispositivos Kunak (eje x) frente a los datos de referencia (eje y), junto con el rango de humedad (eje z). La gr\u00e1fica muestra la correlaci\u00f3n y la ecuaci\u00f3n lineal.\" width=\"1609\" height=\"375\" srcset=\"https:\/\/kunakair.com\/wp-content\/uploads\/2026\/03\/figure-4.jpg 1609w, https:\/\/kunakair.com\/wp-content\/uploads\/2026\/03\/figure-4-1280x298.jpg 1280w, https:\/\/kunakair.com\/wp-content\/uploads\/2026\/03\/figure-4-980x228.jpg 980w, https:\/\/kunakair.com\/wp-content\/uploads\/2026\/03\/figure-4-480x112.jpg 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) and (max-width: 1280px) 1280px, (min-width: 1281px) 1609px, 100vw\" \/><p id=\"caption-attachment-67682\" class=\"wp-caption-text\">Figura 4. <br \/>Gr\u00e1fica de dispersi\u00f3n de los dispositivos Kunak (eje x) frente a los datos de referencia (eje y), junto con el rango de humedad (eje z). La gr\u00e1fica muestra la correlaci\u00f3n y la ecuaci\u00f3n lineal.<\/p><\/div>\n<p>&nbsp;<\/p>\n<p>La Figura 5 muestra c\u00f3mo la concentraci\u00f3n de PM<sub>10<\/sub> es superior a la de PM<sub>2.5<\/sub>, evidenciando una alta concentraci\u00f3n de part\u00edculas gruesas (PM<sub>10<\/sub> \u2013 PM<sub>2.5<\/sub>) monitorizadas durante el ensayo de campo.<\/p>\n<div id=\"attachment_67683\" style=\"width: 1658px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-67683\" class=\"wp-image-67683 size-full\" src=\"https:\/\/kunakair.com\/wp-content\/uploads\/2026\/03\/figure-5.jpg\" alt=\"Figura 5. Variaci\u00f3n temporal del PM&lt;sub&gt;10&lt;\/sub&gt; de referencia (rojo) y de ambas mediciones de PM&lt;sub&gt;10&lt;\/sub&gt; de Kunak (verde y azul).\" width=\"1648\" height=\"746\" srcset=\"https:\/\/kunakair.com\/wp-content\/uploads\/2026\/03\/figure-5.jpg 1648w, https:\/\/kunakair.com\/wp-content\/uploads\/2026\/03\/figure-5-1280x579.jpg 1280w, https:\/\/kunakair.com\/wp-content\/uploads\/2026\/03\/figure-5-980x444.jpg 980w, https:\/\/kunakair.com\/wp-content\/uploads\/2026\/03\/figure-5-480x217.jpg 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) and (max-width: 1280px) 1280px, (min-width: 1281px) 1648px, 100vw\" \/><p id=\"caption-attachment-67683\" class=\"wp-caption-text\">Figura 5. <br \/>Variaci\u00f3n temporal del PM<sub>10<\/sub> de referencia (rojo) y de ambas mediciones de PM<sub>10<\/sub> de Kunak (verde y azul).<\/p><\/div>\n<p>&nbsp;<\/p>\n<p>La tabla siguiente (Tabla 3) muestra las m\u00e9tricas de an\u00e1lisis descritas en la secci\u00f3n <em>Procedimiento de an\u00e1lisis y caracterizaci\u00f3n<\/em>. Se observa no solo la buena correlaci\u00f3n obtenida en el ensayo de campo, sino tambi\u00e9n un MAE bajo y un intervalo de confianza del 90% adecuado. Adem\u00e1s, se aprecia c\u00f3mo la concentraci\u00f3n media monitorizada por la referencia y por los dispositivos Kunak AIR Pro (DUT, Device Under Test) es muy similar.<\/p>\n<div style=\"display: flex; justify-content: center; margin: 20px 0;\">\n<div style=\"width: 100%; max-width: 80%;\">\n<p style=\"text-align: left; font-weight: bold; margin-bottom: 10px; color: #333;\">Tabla 3. M\u00e9tricas de an\u00e1lisis<\/p>\n<table style=\"border-collapse: collapse; width: 100%; background-color: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.1); border-radius: 8px; overflow: hidden;\">\n<thead>\n<tr style=\"background-color: #f8f9fa; border-bottom: 2px solid #eceeef;\">\n<th style=\"padding: 12px; text-align: left; color: #495057;\">Dispositivo<\/th>\n<th style=\"padding: 12px; text-align: center; color: #495057;\">R<sup>2<\/sup><\/th>\n<th style=\"padding: 12px; text-align: center; color: #495057;\">MAE (\u00b5g\/m<sup>3<\/sup>)<\/th>\n<th style=\"padding: 12px; text-align: center; color: #495057;\">IC 90% (\u00b5g\/m<sup>3<\/sup>)<\/th>\n<th style=\"padding: 12px; text-align: center; color: #495057;\">Media GC REF (\u00b5g\/m<sup>3<\/sup>)<\/th>\n<th style=\"padding: 12px; text-align: center; color: #495057;\">Media GC DUT (\u00b5g\/m<sup>3<\/sup>)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr style=\"border-bottom: 1px solid #eceeef;\">\n<td style=\"padding: 12px; font-weight: bold; color: #333;\">K-A3 RENT 1<\/td>\n<td style=\"padding: 12px; text-align: center;\">0.82<\/td>\n<td style=\"padding: 12px; text-align: center;\">10.03<\/td>\n<td style=\"padding: 12px; text-align: center;\">25.39<\/td>\n<td style=\"padding: 12px; text-align: center;\">32.37<\/td>\n<td style=\"padding: 12px; text-align: center;\">33.71<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 12px; font-weight: bold; color: #333;\">K-A3 RENT 4<\/td>\n<td style=\"padding: 12px; text-align: center;\">0.85<\/td>\n<td style=\"padding: 12px; text-align: center;\">9.28<\/td>\n<td style=\"padding: 12px; text-align: center;\">20.63<\/td>\n<td style=\"padding: 12px; text-align: center;\">32.37<\/td>\n<td style=\"padding: 12px; text-align: center;\">28.24<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<p>Todos estos gr\u00e1ficos y estad\u00edsticas muestran el buen rendimiento del sensor de part\u00edculas para monitorizar altas concentraciones de PM<sub>10<\/sub> en presencia de part\u00edculas gruesas.<\/p>\n<h4>2. Ensayo de campo: Accra, Ghana<\/h4>\n<ul>\n<li><strong>Ubicaci\u00f3n<\/strong>: Accra, Ghana.<\/li>\n<li><strong>Periodo de ensayo<\/strong>: del 8 de enero al 18 de febrero de 2024.<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<div style=\"display: flex; justify-content: center; margin: 20px 0;\">\n<div style=\"width: 100%; max-width: 50%;\">\n<p style=\"text-align: left; font-weight: bold; margin-bottom: 10px; color: #333;\">Tabla 4. Condiciones ambientales del ensayo de campo<\/p>\n<table style=\"border-collapse: collapse; width: 100%; background-color: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.1); border-radius: 8px; overflow: hidden;\">\n<thead>\n<tr style=\"background-color: #f8f9fa; border-bottom: 2px solid #eceeef;\">\n<th style=\"padding: 12px; text-align: left; color: #495057;\">Par\u00e1metro<\/th>\n<th style=\"padding: 12px; text-align: center; color: #495057;\">M\u00edn<\/th>\n<th style=\"padding: 12px; text-align: center; color: #495057;\">Media<\/th>\n<th style=\"padding: 12px; text-align: center; color: #495057;\">M\u00e1x<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr style=\"border-bottom: 1px solid #eceeef;\">\n<td style=\"padding: 12px; font-weight: bold; color: #333;\">T (\u00b0C)<\/td>\n<td style=\"padding: 12px; text-align: center;\">24.05<\/td>\n<td style=\"padding: 12px; text-align: center;\">30.03<\/td>\n<td style=\"padding: 12px; text-align: center;\">38.78<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 12px; font-weight: bold; color: #333;\">RH (%)<\/td>\n<td style=\"padding: 12px; text-align: center;\">17.25<\/td>\n<td style=\"padding: 12px; text-align: center;\">73.18<\/td>\n<td style=\"padding: 12px; text-align: center;\">96.30<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<div style=\"display: flex; justify-content: center; margin: 20px 0;\">\n<div style=\"width: 100%; max-width: 70%;\">\n<p style=\"text-align: left; font-weight: bold; margin-bottom: 10px; color: #333;\">Tabla 5. Estad\u00edsticas de PM<sub>2.5<\/sub> y PM<sub>10<\/sub> medidas por la estaci\u00f3n de calidad del aire (referencia)<\/p>\n<table style=\"border-collapse: collapse; width: 100%; background-color: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.1); border-radius: 8px; overflow: hidden;\">\n<thead>\n<tr style=\"background-color: #f8f9fa; border-bottom: 2px solid #eceeef;\">\n<th style=\"padding: 12px; text-align: left; color: #495057;\">Estaci\u00f3n<\/th>\n<th style=\"padding: 12px; text-align: left; color: #495057;\">Sensor<\/th>\n<th style=\"padding: 12px; text-align: center; color: #495057;\">Media<\/th>\n<th style=\"padding: 12px; text-align: center; color: #495057;\">M\u00e1ximo<\/th>\n<th style=\"padding: 12px; text-align: center; color: #495057;\">M\u00ednimo<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr style=\"border-bottom: 1px solid #eceeef;\">\n<td style=\"padding: 12px; font-weight: bold; color: #333; vertical-align: middle; border-right: 1px solid #eceeef;\" rowspan=\"2\">RS Ghana Accra<\/td>\n<td style=\"padding: 12px; color: #555;\">PM<sub>2.5<\/sub> (\u00b5g\/m<sup>3<\/sup>)<\/td>\n<td style=\"padding: 12px; text-align: center;\">84.66<\/td>\n<td style=\"padding: 12px; text-align: center;\">350.73<\/td>\n<td style=\"padding: 12px; text-align: center;\">14.76<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 12px; color: #555;\">PM<sub>10<\/sub> (\u00b5g\/m<sup>3<\/sup>)<\/td>\n<td style=\"padding: 12px; text-align: center;\">325.60<\/td>\n<td style=\"padding: 12px; text-align: center;\">1493.95<\/td>\n<td style=\"padding: 12px; text-align: center;\">32.35<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<p>La siguiente figura (Figura 6) muestra el gr\u00e1fico temporal con las mediciones registradas por la estaci\u00f3n de referencia y los tres dispositivos Kunak AIR Pro. Como se observa, hay aproximadamente dos semanas en las que las concentraciones superan el l\u00edmite de 190 \u00b5g\/m<sup>3<\/sup> durante la mayor parte del tiempo. El gr\u00e1fico muestra c\u00f3mo las mediciones de PM<sub>10<\/sub> de Kunak est\u00e1n alineadas con las mediciones de PM<sub>10<\/sub> registradas por el analizador de part\u00edculas.<\/p>\n<div id=\"attachment_67684\" style=\"width: 1072px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-67684\" class=\"wp-image-67684 size-full\" src=\"https:\/\/kunakair.com\/wp-content\/uploads\/2026\/03\/figure-6.jpg\" alt=\"\" width=\"1062\" height=\"411\" srcset=\"https:\/\/kunakair.com\/wp-content\/uploads\/2026\/03\/figure-6.jpg 1062w, https:\/\/kunakair.com\/wp-content\/uploads\/2026\/03\/figure-6-980x379.jpg 980w, https:\/\/kunakair.com\/wp-content\/uploads\/2026\/03\/figure-6-480x186.jpg 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1062px, 100vw\" \/><p id=\"caption-attachment-67684\" class=\"wp-caption-text\">Figura 6. <br \/>Gr\u00e1fico temporal de PM<sub>2.5<\/sub> y PM<sub>10<\/sub> de referencia.<\/p><\/div>\n<p>&nbsp;<\/p>\n<p>La buena correlaci\u00f3n entre los dispositivos Kunak AIR Pro y los datos de referencia se muestra en la Figura 7, donde se incluyen el diagrama de dispersi\u00f3n, la correlaci\u00f3n (R<sup>2<\/sup>) y la ecuaci\u00f3n lineal. Los tres sistemas de sensores Kunak AIR Pro presentan una correlaci\u00f3n excelente, superior a 0.87, con una pendiente cercana a 1. En este caso, debido a las concentraciones muy elevadas, el offset es ligeramente mayor (en torno a 26-40 \u00b5g\/m<sup>3<\/sup>). Considerando concentraciones superiores a 250 \u00b5g\/m<sup>3<\/sup>, este intercepto puede considerarse despreciable.<\/p>\n<div id=\"attachment_67685\" style=\"width: 1288px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-67685\" class=\"wp-image-67685 size-full\" src=\"https:\/\/kunakair.com\/wp-content\/uploads\/2026\/03\/figure-7.jpg\" alt=\"\" width=\"1278\" height=\"445\" srcset=\"https:\/\/kunakair.com\/wp-content\/uploads\/2026\/03\/figure-7.jpg 1278w, https:\/\/kunakair.com\/wp-content\/uploads\/2026\/03\/figure-7-980x341.jpg 980w, https:\/\/kunakair.com\/wp-content\/uploads\/2026\/03\/figure-7-480x167.jpg 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1278px, 100vw\" \/><p id=\"caption-attachment-67685\" class=\"wp-caption-text\">Figura 7. <br \/>Gr\u00e1fico temporal de PM<sub>10<\/sub> de referencia (azul) y mediciones de PM<sub>10<\/sub> de Kunak: dispositivos K-A3 GHANA 1 (amarillo), K-A3 GHANA 2 (verde) y K-A3 GHANA 3 (naranja). La l\u00ednea roja indica el l\u00edmite de concentraci\u00f3n de PM<sub>10<\/sub> de 190 \u00b5g\/m<sup>3<\/sup>.<\/p><\/div>\n<p>&nbsp;<\/p>\n<p>La Figura 8 muestra el gr\u00e1fico de variaci\u00f3n temporal, en el que se observa c\u00f3mo los sensores de part\u00edculas Kunak de los tres dispositivos siguen perfectamente las tendencias del PM<sub>10<\/sub> medidas por el analizador de referencia.<\/p>\n<div id=\"attachment_67686\" style=\"width: 1623px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-67686\" class=\"wp-image-67686 size-full\" src=\"https:\/\/kunakair.com\/wp-content\/uploads\/2026\/03\/figure-8.jpg\" alt=\"Figura 8. Diagrama de dispersi\u00f3n de los dispositivos Kunak (eje X) frente a los datos de referencia (eje Y), y rango de humedad (eje Z). El gr\u00e1fico muestra la correlaci\u00f3n y la ecuaci\u00f3n lineal.\" width=\"1613\" height=\"782\" srcset=\"https:\/\/kunakair.com\/wp-content\/uploads\/2026\/03\/figure-8.jpg 1613w, https:\/\/kunakair.com\/wp-content\/uploads\/2026\/03\/figure-8-1280x621.jpg 1280w, https:\/\/kunakair.com\/wp-content\/uploads\/2026\/03\/figure-8-980x475.jpg 980w, https:\/\/kunakair.com\/wp-content\/uploads\/2026\/03\/figure-8-480x233.jpg 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) and (max-width: 1280px) 1280px, (min-width: 1281px) 1613px, 100vw\" \/><p id=\"caption-attachment-67686\" class=\"wp-caption-text\">Figura 8. Diagrama de dispersi\u00f3n de los dispositivos Kunak (eje X) frente a los datos de referencia (eje Y), y rango de humedad (eje Z). El gr\u00e1fico muestra la correlaci\u00f3n y la ecuaci\u00f3n lineal.<\/p><\/div>\n<p>&nbsp;<\/p>\n<div id=\"attachment_67687\" style=\"width: 1564px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-67687\" class=\"wp-image-67687 size-full\" src=\"https:\/\/kunakair.com\/wp-content\/uploads\/2026\/03\/figure-9.jpg\" alt=\"\" width=\"1554\" height=\"709\" srcset=\"https:\/\/kunakair.com\/wp-content\/uploads\/2026\/03\/figure-9.jpg 1554w, https:\/\/kunakair.com\/wp-content\/uploads\/2026\/03\/figure-9-1280x584.jpg 1280w, https:\/\/kunakair.com\/wp-content\/uploads\/2026\/03\/figure-9-980x447.jpg 980w, https:\/\/kunakair.com\/wp-content\/uploads\/2026\/03\/figure-9-480x219.jpg 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) and (max-width: 1280px) 1280px, (min-width: 1281px) 1554px, 100vw\" \/><p id=\"caption-attachment-67687\" class=\"wp-caption-text\">Figura 9. <br \/>Variaci\u00f3n temporal de la referencia (morado) y de las tres mediciones de PM<sub>10<\/sub> de Kunak (rojo, verde y azul).<\/p><\/div>\n<p>&nbsp;<\/p>\n<p>Por \u00faltimo, la tabla 6 muestra las m\u00e9tricas de an\u00e1lisis descritas en la secci\u00f3n <em>Procedimiento de an\u00e1lisis y caracterizaci\u00f3n<\/em>, donde se evidencia la excelente correlaci\u00f3n obtenida en el ensayo de campo.<\/p>\n<p>Como se ha mencionado anteriormente, debido a las concentraciones muy elevadas, el MAE y el intervalo de confianza del 90% son mayores que en el ensayo de Helsinki. Esto es esperable, ya que el rango de concentraci\u00f3n va de 32.35 a 1493.94 \u00b5g\/m<sup>3<\/sup>.<\/p>\n<p>Por \u00faltimo, la tabla muestra la concentraci\u00f3n media monitorizada tanto por la referencia como por el DUT (Device Under Test), evidenciando valores muy similares entre ambas tecnolog\u00edas.<\/p>\n<div style=\"display: flex; justify-content: center; margin: 20px 0;\">\n<div style=\"width: 100%; max-width: 85%;\">\n<p style=\"text-align: left; font-weight: bold; margin-bottom: 10px; color: #333;\">Tabla 6. M\u00e9tricas de an\u00e1lisis.<\/p>\n<table style=\"border-collapse: collapse; width: 100%; background-color: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.1); border-radius: 8px; overflow: hidden;\">\n<thead>\n<tr style=\"background-color: #f8f9fa; border-bottom: 2px solid #eceeef;\">\n<th style=\"padding: 12px; text-align: left; color: #495057;\">Dispositivo<\/th>\n<th style=\"padding: 12px; text-align: center; color: #495057;\">R<sup>2<\/sup><\/th>\n<th style=\"padding: 12px; text-align: center; color: #495057;\">MAE (\u00b5g\/m<sup>3<\/sup>)<\/th>\n<th style=\"padding: 12px; text-align: center; color: #495057;\">IC 90% (\u00b5g\/m<sup>3<\/sup>)<\/th>\n<th style=\"padding: 12px; text-align: center; color: #495057;\">Media GC REF (\u00b5g\/m<sup>3<\/sup>)<\/th>\n<th style=\"padding: 12px; text-align: center; color: #495057;\">Media GC DUT (\u00b5g\/m<sup>3<\/sup>)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr style=\"border-bottom: 1px solid #eceeef;\">\n<td style=\"padding: 12px; font-weight: bold; color: #333;\">K-A3 GHANA 1<\/td>\n<td style=\"padding: 12px; text-align: center;\">0.89<\/td>\n<td style=\"padding: 12px; text-align: center;\">75.89<\/td>\n<td style=\"padding: 12px; text-align: center;\">255.92<\/td>\n<td style=\"padding: 12px; text-align: center;\">325.60<\/td>\n<td style=\"padding: 12px; text-align: center;\">257.85<\/td>\n<\/tr>\n<tr style=\"border-bottom: 1px solid #eceeef;\">\n<td style=\"padding: 12px; font-weight: bold; color: #333;\">K-A3 GHANA 2<\/td>\n<td style=\"padding: 12px; text-align: center;\">0.92<\/td>\n<td style=\"padding: 12px; text-align: center;\">64.87<\/td>\n<td style=\"padding: 12px; text-align: center;\">214.26<\/td>\n<td style=\"padding: 12px; text-align: center;\">325.60<\/td>\n<td style=\"padding: 12px; text-align: center;\">313.39<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 12px; font-weight: bold; color: #333;\">K-A3 GHANA 3<\/td>\n<td style=\"padding: 12px; text-align: center;\">0.87<\/td>\n<td style=\"padding: 12px; text-align: center;\">92.60<\/td>\n<td style=\"padding: 12px; text-align: center;\">312.65<\/td>\n<td style=\"padding: 12px; text-align: center;\">325.60<\/td>\n<td style=\"padding: 12px; text-align: center;\">232.73<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<p>Todos estos gr\u00e1ficos y estad\u00edsticas muestran el buen rendimiento del sensor de part\u00edculas para monitorizar altas concentraciones de PM<sub>10<\/sub> en presencia de part\u00edculas gruesas.<\/p>\n<h2>Conclusiones<\/h2>\n<p>Los ensayos de campo realizados en Helsinki, Finlandia, y Accra, Ghana, demuestran que el sensor PM integrado en <strong>Kunak AIR Pro ofrece un rendimiento s\u00f3lido y consistente<\/strong>, incluso en condiciones con altas concentraciones de part\u00edculas gruesas.<\/p>\n<p>En ambas ubicaciones, los dispositivos Kunak AIR Pro mostraron un <strong>buen comportamiento frente a analizadores de referencia<\/strong>, con valores de correlaci\u00f3n R<sup>2<\/sup> superiores a 0,80 en Helsinki y a 0,87 en Accra, lo que confirma su capacidad para reproducir con precisi\u00f3n tanto las tendencias de PM<sub>10<\/sub> como los <strong>niveles absolutos de concentraci\u00f3n<\/strong>.<\/p>\n<p>Los resultados indican que el sensor mantiene un <strong>comportamiento estable<\/strong> en un amplio rango de temperaturas, niveles de humedad y cargas de part\u00edculas, conservando una <strong>alta precisi\u00f3n<\/strong> tanto en condiciones moderadas como en episodios severos de contaminaci\u00f3n. Aunque el MAE y el intervalo de confianza del 90% aumentan bajo concentraciones extremadamente altas, como era esperable por el rango operativo m\u00e1s amplio observado en Accra, la buena alineaci\u00f3n entre los dispositivos Kunak AIR Pro y los instrumentos equivalentes confirma la <strong>robustez del sistema<\/strong>.<\/p>\n<div class=\"kunak-cita-destacada\">En conjunto, los resultados de ambos estudios validan a Kunak AIR Pro como una herramienta fiable y eficaz para la monitorizaci\u00f3n indicativa de PM<sub>10<\/sub> en entornos dominados por part\u00edculas gruesas.<\/div>\n<p>Su capacidad para <strong>seguir con precisi\u00f3n las variaciones temporales<\/strong>, detectar <strong>picos de concentraci\u00f3n<\/strong> y mantener una <strong>buena concordancia con equipos de referencia<\/strong> la hace adecuada para aplicaciones industriales, urbanas y operativas en escenarios de construcci\u00f3n y demolici\u00f3n, donde disponer de datos fiables de calidad del aire es esencial para la toma de decisiones y la gesti\u00f3n ambiental.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Contexto El material particulado (PM) no es un \u00fanico contaminante, sino una mezcla de part\u00edculas de distintos tama\u00f1os, composiciones y or\u00edgenes. El tama\u00f1o de estas part\u00edculas determina cu\u00e1nto tiempo permanecen suspendidas en el aire y hasta qu\u00e9 punto penetran en el sistema respiratorio humano. Para fines regulatorios y de monitorizaci\u00f3n ambiental, dos fracciones son especialmente [&hellip;]<\/p>\n","protected":false},"author":4,"featured_media":67796,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":"","footnotes":""},"categories":[164],"tags":[],"resources":[394],"class_list":["post-67797","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articulos","resources-contaminacion-y-salud"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Medici\u00f3n de PM10 en entornos con part\u00edculas gruesas - Kunak<\/title>\n<meta name=\"description\" content=\"Medici\u00f3n de PM10 en entornos con part\u00edculas gruesas: c\u00f3mo la tecnolog\u00eda de sensores garantiza datos precisos, fiables y en tiempo real\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/kunakair.com\/es\/medicion-de-pm10-en-entornos-con-alta-presencia-de-particulas-gruesas\/\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Medici\u00f3n de PM10 en entornos con part\u00edculas gruesas - Kunak\" \/>\n<meta property=\"og:description\" content=\"Medici\u00f3n de PM10 en entornos con part\u00edculas gruesas: c\u00f3mo la tecnolog\u00eda de sensores garantiza datos precisos, fiables y en tiempo real\" \/>\n<meta property=\"og:url\" content=\"https:\/\/kunakair.com\/es\/medicion-de-pm10-en-entornos-con-alta-presencia-de-particulas-gruesas\/\" \/>\n<meta property=\"og:site_name\" content=\"Kunak\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/KunakTechnologies\/\" \/>\n<meta property=\"article:published_time\" content=\"2026-04-13T13:29:36+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-04-14T15:28:22+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/kunakair.com\/wp-content\/uploads\/2026\/03\/PM10-measurement-in-coarse-particle-environments.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1800\" \/>\n\t<meta property=\"og:image:height\" content=\"1200\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Edurne Ibarrola-Ulzurrun, PhD\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@KunaK_sensing\" \/>\n<meta name=\"twitter:site\" content=\"@KunaK_sensing\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t<meta name=\"twitter:data1\" content=\"Edurne Ibarrola-Ulzurrun, PhD\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tiempo de lectura\" \/>\n\t<meta name=\"twitter:data2\" content=\"18 minutos\" \/>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Medici\u00f3n de PM10 en entornos con part\u00edculas gruesas - Kunak","description":"Medici\u00f3n de PM10 en entornos con part\u00edculas gruesas: c\u00f3mo la tecnolog\u00eda de sensores garantiza datos precisos, fiables y en tiempo real","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/kunakair.com\/es\/medicion-de-pm10-en-entornos-con-alta-presencia-de-particulas-gruesas\/","og_locale":"es_ES","og_type":"article","og_title":"Medici\u00f3n de PM10 en entornos con part\u00edculas gruesas - Kunak","og_description":"Medici\u00f3n de PM10 en entornos con part\u00edculas gruesas: c\u00f3mo la tecnolog\u00eda de sensores garantiza datos precisos, fiables y en tiempo real","og_url":"https:\/\/kunakair.com\/es\/medicion-de-pm10-en-entornos-con-alta-presencia-de-particulas-gruesas\/","og_site_name":"Kunak","article_publisher":"https:\/\/www.facebook.com\/KunakTechnologies\/","article_published_time":"2026-04-13T13:29:36+00:00","article_modified_time":"2026-04-14T15:28:22+00:00","og_image":[{"width":1800,"height":1200,"url":"https:\/\/kunakair.com\/wp-content\/uploads\/2026\/03\/PM10-measurement-in-coarse-particle-environments.jpg","type":"image\/jpeg"}],"author":"Edurne Ibarrola-Ulzurrun, PhD","twitter_card":"summary_large_image","twitter_creator":"@KunaK_sensing","twitter_site":"@KunaK_sensing","twitter_misc":{"Escrito por":"Edurne Ibarrola-Ulzurrun, PhD","Tiempo de lectura":"18 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/kunakair.com\/es\/medicion-de-pm10-en-entornos-con-alta-presencia-de-particulas-gruesas\/#article","isPartOf":{"@id":"https:\/\/kunakair.com\/es\/medicion-de-pm10-en-entornos-con-alta-presencia-de-particulas-gruesas\/"},"author":{"name":"Edurne Ibarrola-Ulzurrun, PhD","@id":"https:\/\/kunakair.com\/es\/#\/schema\/person\/cfca8d61d67be081e89f479b27605a9f"},"headline":"Medici\u00f3n de PM10 en entornos con alta presencia de part\u00edculas gruesas: por qu\u00e9 importa la tecnolog\u00eda del sensor","datePublished":"2026-04-13T13:29:36+00:00","dateModified":"2026-04-14T15:28:22+00:00","mainEntityOfPage":{"@id":"https:\/\/kunakair.com\/es\/medicion-de-pm10-en-entornos-con-alta-presencia-de-particulas-gruesas\/"},"wordCount":3205,"publisher":{"@id":"https:\/\/kunakair.com\/es\/#organization"},"image":{"@id":"https:\/\/kunakair.com\/es\/medicion-de-pm10-en-entornos-con-alta-presencia-de-particulas-gruesas\/#primaryimage"},"thumbnailUrl":"https:\/\/kunakair.com\/wp-content\/uploads\/2026\/03\/PM10-measurement-in-coarse-particle-environments.jpg","articleSection":["Art\u00edculos"],"inLanguage":"es"},{"@type":"WebPage","@id":"https:\/\/kunakair.com\/es\/medicion-de-pm10-en-entornos-con-alta-presencia-de-particulas-gruesas\/","url":"https:\/\/kunakair.com\/es\/medicion-de-pm10-en-entornos-con-alta-presencia-de-particulas-gruesas\/","name":"Medici\u00f3n de PM10 en entornos con part\u00edculas gruesas - Kunak","isPartOf":{"@id":"https:\/\/kunakair.com\/es\/#website"},"primaryImageOfPage":{"@id":"https:\/\/kunakair.com\/es\/medicion-de-pm10-en-entornos-con-alta-presencia-de-particulas-gruesas\/#primaryimage"},"image":{"@id":"https:\/\/kunakair.com\/es\/medicion-de-pm10-en-entornos-con-alta-presencia-de-particulas-gruesas\/#primaryimage"},"thumbnailUrl":"https:\/\/kunakair.com\/wp-content\/uploads\/2026\/03\/PM10-measurement-in-coarse-particle-environments.jpg","datePublished":"2026-04-13T13:29:36+00:00","dateModified":"2026-04-14T15:28:22+00:00","description":"Medici\u00f3n de PM10 en entornos con part\u00edculas gruesas: c\u00f3mo la tecnolog\u00eda de sensores garantiza datos precisos, fiables y en tiempo real","breadcrumb":{"@id":"https:\/\/kunakair.com\/es\/medicion-de-pm10-en-entornos-con-alta-presencia-de-particulas-gruesas\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/kunakair.com\/es\/medicion-de-pm10-en-entornos-con-alta-presencia-de-particulas-gruesas\/"]}]},{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/kunakair.com\/es\/medicion-de-pm10-en-entornos-con-alta-presencia-de-particulas-gruesas\/#primaryimage","url":"https:\/\/kunakair.com\/wp-content\/uploads\/2026\/03\/PM10-measurement-in-coarse-particle-environments.jpg","contentUrl":"https:\/\/kunakair.com\/wp-content\/uploads\/2026\/03\/PM10-measurement-in-coarse-particle-environments.jpg","width":1800,"height":1200,"caption":"PM10 measurement in coarse particle environments: why sensor technology matters"},{"@type":"BreadcrumbList","@id":"https:\/\/kunakair.com\/es\/medicion-de-pm10-en-entornos-con-alta-presencia-de-particulas-gruesas\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/kunakair.com\/es\/"},{"@type":"ListItem","position":2,"name":"Medici\u00f3n de PM10 en entornos con alta presencia de part\u00edculas gruesas: por qu\u00e9 importa la tecnolog\u00eda del sensor"}]},{"@type":"WebSite","@id":"https:\/\/kunakair.com\/es\/#website","url":"https:\/\/kunakair.com\/es\/","name":"KUNAK","description":"Sensing anywhere","publisher":{"@id":"https:\/\/kunakair.com\/es\/#organization"},"alternateName":"Sensing anywhere","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/kunakair.com\/es\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"},{"@type":"Organization","@id":"https:\/\/kunakair.com\/es\/#organization","name":"KUNAK","alternateName":"Sensing anywhere","url":"https:\/\/kunakair.com\/es\/","logo":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/kunakair.com\/es\/#\/schema\/logo\/image\/","url":"https:\/\/kunakair.com\/wp-content\/uploads\/2022\/09\/logo-kunak-cuadrado.jpg","contentUrl":"https:\/\/kunakair.com\/wp-content\/uploads\/2022\/09\/logo-kunak-cuadrado.jpg","width":1000,"height":1000,"caption":"KUNAK"},"image":{"@id":"https:\/\/kunakair.com\/es\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/KunakTechnologies\/","https:\/\/x.com\/KunaK_sensing","https:\/\/www.linkedin.com\/company\/kunak\/","https:\/\/www.instagram.com\/kunak_technologies\/","https:\/\/www.youtube.com\/channel\/UC-suigTybwCW50od_rhTZxg"]},{"@type":"Person","@id":"https:\/\/kunakair.com\/es\/#\/schema\/person\/cfca8d61d67be081e89f479b27605a9f","name":"Edurne Ibarrola-Ulzurrun, PhD","description":"Dr. Edurne Ibarrola-Ulzurrun is Scientific Director (CSO) at Kunak Technologies. She received a degree in biology at the University of Navarra (Spain) and the M.sc at the University of Tromso (Norway) in 2012 and 2014, respectively. She obtained a PhD degree in remote sensing and environmental science from the University of Las Palmas de Gran Canaria, Spain in 2019. She is responsible for innovation and development tasks in air quality sensor-based devices, such as improving sensors' behaviour, dealing with all their challenges and working on how to improve the accuracy of the data. She works on research and development projects with universities and research centres, giving support related to air quality and sensor-based instrument performance. She is, also responsible for regulation with legislation bodies and certifications. She is a member of the CEN\/TC264\/WG42, which developed technical specification \"UNE-CEN\/TS 17660-1:2021 - Air Quality-Performance evaluation of air quality sensors\" and WG41 \"Emissions and ambient air \u2013 Instrumental odour monitoring\".La Dra. Edurne Ibarrola es la Directora Cient\u00edfica (CSO) de Kunak Technologies. Se licenci\u00f3 en biolog\u00eda en la Universidad de Navarra (Espa\u00f1a) y obtuvo el M.sc en la Universidad de Tromso (Noruega) en 2012 y 2014, respectivamente. Obtuvo el t\u00edtulo de doctora en teledetecci\u00f3n y ciencias ambientales por la Universidad de Las Palmas de Gran Canaria (Espa\u00f1a) en 2019. Es responsable de tareas de innovaci\u00f3n y desarrollo en dispositivos basados en sensores de calidad del aire, como mejorar el comportamiento de los sensores, abordar todos sus desaf\u00edos y trabajar en c\u00f3mo mejorar la precisi\u00f3n de los datos. Trabaja en proyectos de investigaci\u00f3n y desarrollo con universidades y centros de investigaci\u00f3n, prestando apoyo en relaci\u00f3n con la calidad del aire y el rendimiento de los instrumentos basados en sensores. Tambi\u00e9n es responsable de la regulaci\u00f3n con organismos legislativos y certificaciones. Es miembro del CEN\/TC264\/WG42, que desarroll\u00f3 la especificaci\u00f3n t\u00e9cnica \"UNE-CEN\/TS 17660-1:2021 - Calidad del aire - Evaluaci\u00f3n del rendimiento de los sensores de calidad del aire\" y del WG41 \"Emisiones y aire ambiente - Monitorizaci\u00f3n instrumental de olores\".","sameAs":["https:\/\/www.linkedin.com\/in\/eibarrola\/"],"url":"https:\/\/kunakair.com\/es\/author\/edurne-ibarrola\/"}]}},"_links":{"self":[{"href":"https:\/\/kunakair.com\/es\/wp-json\/wp\/v2\/posts\/67797","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/kunakair.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/kunakair.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/kunakair.com\/es\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/kunakair.com\/es\/wp-json\/wp\/v2\/comments?post=67797"}],"version-history":[{"count":10,"href":"https:\/\/kunakair.com\/es\/wp-json\/wp\/v2\/posts\/67797\/revisions"}],"predecessor-version":[{"id":68000,"href":"https:\/\/kunakair.com\/es\/wp-json\/wp\/v2\/posts\/67797\/revisions\/68000"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/kunakair.com\/es\/wp-json\/wp\/v2\/media\/67796"}],"wp:attachment":[{"href":"https:\/\/kunakair.com\/es\/wp-json\/wp\/v2\/media?parent=67797"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/kunakair.com\/es\/wp-json\/wp\/v2\/categories?post=67797"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/kunakair.com\/es\/wp-json\/wp\/v2\/tags?post=67797"},{"taxonomy":"resources","embeddable":true,"href":"https:\/\/kunakair.com\/es\/wp-json\/wp\/v2\/resources?post=67797"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}